Huaian Shmmech Machinery Manufacturing Co., Ltd.
21/5000 Measures to deal with unbalanced design of control valve device of pneumatic components
Addtime: 2019/11/1 16:43:17  click: 1054
At the beginning of the design, the control valve of pneumatic components can not find a matching, so it will create the imbalance of the whole system, which will cause unnecessary loss of energy consumption, so it is possible to be perfect at the beginning of the system design.
If the system cannot reach full load due to unbalanced design conditions, the total investment of the entire unit will not be returned. When large loads are required, the pneumatic component control valve is fully open and cannot handle this condition. It is very difficult to determine the size of the two-way control valve, the calculated valve is generally not available in the market, so the size is usually larger. In this way, circulatory system balance becomes very critical. Generally speaking, the input of this part is less than 1% of the total investment of hvac. Every morning, after overnight downtime, full power is needed to restore comfort as quickly as possible. A well-balanced system can be done quickly. If the startup time can be saved by 30 minutes, the energy consumption can be saved by 6% per day, compared with 8 hours of working time. This is more than all the allocated pumping costs.
In variable flow distribution, pumping energy consumption generally accounts for less than 5% of the seasonal consumption of refrigeration units. And the charge that reduces indoor temperature more 1 degree need is 10 to 16%. Therefore, getting the right comfort level is a better way to save energy. Therefore, all measures designed to reduce pumping energy consumption must be taken so that they do not adversely affect the operation of the control loop of the terminal device. By maximizing the design water temperature difference. T and using better positioning Δ p sensor of variable speed pump, can reduce the cost of pumping. Under medium loads, stable adjustable PI control requires less flow than switching control, thus reducing pumping costs.
But more important is the size of the compensation pump. The balance valve provided by the compensation method can display such oversized condition. All overpressure can be found on the balance valve near the pump. After the pump is modified, the pneumatic element balancing valve can be reopened. Cyclic balancing requires the right tools, newer procedures, and effective measuring devices. The pneumatic component manual balancing valve is obviously a more reliable, simpler product to obtain the correct flow under design conditions and is always capable of measuring the flow for diagnosis. It can also be connected to the differential pressure controller if necessary.
Some of the articles and information on this website are from the Internet. Reprinting on this website for the purpose of transmitting more information and learning does not mean agreeing with the opinions or confirming the authenticity of the content. If reprint the manuscript involves the copyright and so on question, please immediately contact the administrator, we will give the change or the deletion related article, guarantees your right.
[Go back to the previous page]
Sales phone: 15189699567
  13511554862
Address: no. 143 changjiang east road, huaiyin district, huaian, China
Email: shmmech_sales@163.com
Alibaba store: https://shmmech.1688.com
Website: http://www.m.cyberly.cn
This website is some pictures from the network, if there are any infringement, please inform us to delete
Web site for the record number: Sue ICP for 2022005973-1
主站蜘蛛池模板: 安达市| 高雄县| 文安县| 龙江县| 孝感市| 瓮安县| 丹江口市| 洪泽县| 塔城市| 徐州市| 佛学| 义乌市| 中山市| 平武县| 年辖:市辖区| 开阳县| 石棉县| 桂阳县| 庐江县| 交口县| 堆龙德庆县| 礼泉县| 滕州市| 临夏县| 贺州市| 灌南县| 闸北区| 水富县| 枣庄市| 福清市| 桦南县| 武乡县| 天祝| 九龙坡区| 衡南县| 安泽县| 屏南县| 新津县| 郯城县| 应城市| 黔西|